Pioneering Framework Could Reduce Energy Demand in Homes and Buildings

Posted on
Thermal Interactions Schematic
Schematic of thermal interactions with the environment and energy transfers needed for the theoretical minimum thermal load (TMTL) calculation. Credit: Julia Laser and Josh Bauer, NREL

Researchers make a case for shifting how we think about heating and cooling needs in buildings.

Heating and cooling buildings is a large part of global energy demand and a significant CO2 and greenhouse gas emissions source. In the coming decades, the energy demand for heating and cooling – also known as thermal energy – is expected to grow considerably. Scientists and engineers have made many advances in lowering building energy demand by improving energy efficiency in building technologies and reducing energy loss through the building walls and windows.

Now, researchers are concerned that simply tackling the problem through energy-efficient technology and design will reach its practical limits. Researchers from Lawrence Berkeley National Laboratory (Berkeley Lab), the National Renewable Energy Laboratory, and UC Berkeley have pioneered a new framework that determines the minimum thermal energy required to keep building occupants comfortable.

In a recently published study in the journal Joule, they make a case for calculating the theoretical minimum thermal load to lower the energy required for heating and cooling buildings dramatically.

“Our work shows that current thermal loads in buildings are more than an order-of-magnitude higher than the theoretical minimum thermal load,” said Ravi Prasher, Berkeley Lab’s Associate Lab Director for Energy Technologies and the corresponding author of the paper. “In fact, the theoretical minimum thermal load showed that in residential buildings the energy used for heating or cooling an entire building for occupant comfort could be between 19 to 40 times lower.”

The theoretical minimum thermal load does not calculate the amount of heating or cooling needed to make an uncomfortable space comfortable. Still, rather it sets up a new baseline for occupant comfort with different building parameters. By calculating this baseline, the researchers identify the physical limit for reduced thermal energy use, that is, the point at which further reduction in thermal energy would cause occupant discomfort. Read more at the Building Technology & Urban Systems Division website. Source